Impact of positioning errors in the dosimetry of VMAT left-sided post mastectomy irradiation

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Sichuan Cancer Hospital & Research Institute, School of Medicine University of Electronic Science and Technology of China, 55th Renmin South Road, 4th Section, Chengdu 610041, China
出处:
ISSN:

关键词: Radiotherapy Breast cancer Volumetric modulated arc therapy Positioning errors Heart dose

摘要:
Background Volumetric modulated arc therapy (VMAT) adopted in post-mastectomy radiation therapy (PMRT) has the capacity to achieve highly conformal dose distributions. The research aims to evaluate the impact of positioning errors in the dosimetry of VMAT left-sided PMRT. Methods A total of 18 perturbations where introduced in 11 VMAT treatment plans that shifted the isocenter from its reference position of 3, 5, 10 mm in six directions. The thoracic wall and supraclavicular clinical target volumes (CTVs), the heart and the left lung dose volume histograms (DVHs) of 198 perturbed plans were calculated. The absolute differences ( increment ) of the mean dose (Dm) and DVH endpoints Vx and Dy (percentage volume receiving x Gy, and dose covering y% of the volume, respectively) were used to compare the dosimetry of the reference vs perturbed plans. Results Isocenter shifts in the anterior and lateral directions lead to maximum disagreement between the CTVs dosimetry of perturbed vs reference plans. Isocenter shifts of 10 mm shown a decrease of D95, D98 and Dm of 12.8, 18.0, and 2.9% respectively, for the CTVs. For 5 mm isocenter shifts, these differences decreased to 3.2, 5.2, and 0.9%, respectively, and for 3 mm shifts to 1.0, 1.7, and 0.6%, respectively. For the organs at risk (OARs), only isocenter shifts in the right, posterior and inferior directions worsen the plan dosimetry, nevertheless not negligible lung increment V20 of + 2.6%, and heart increment V25 of + 1.6% persist for 3 mm shifts. Conclusions Inaccuracy in isocenter positioning for VMAT left-sided PMRT irradiation may impact the dosimetry of the CTVs and OARs to a different extent, depending on the directions and magnitude of the perturbation. The acquired information could be useful for planning strategies to guarantee the accuracy of the treatment delivered.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 2 区 核医学 3 区 肿瘤学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学 3 区 肿瘤学
JCR分区:
出版当年[2020]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q3 ONCOLOGY
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Sichuan Cancer Hospital & Research Institute, School of Medicine University of Electronic Science and Technology of China, 55th Renmin South Road, 4th Section, Chengdu 610041, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43377 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号