Evaluation of interfraction setup variations for postmastectomy radiation therapy using EPID-based in vivo dosimetry

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China [2]Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, Chengdu, China [3]Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China [4]UOC Fisica Sanitaria, Fondazione Policlinico Universitario Agostino Gemelli, Rome, Italy
出处:
ISSN:

关键词: breast radiotherapy in vivo dosimetry volumetric modulated arc therapy

摘要:
Postmastectomy radiation therapy is technically difficult and can be considered one of the most complex techniques concerning patient setup reproducibility. Slight patient setup variations - particularly when high-conformal treatment techniques are used - can adversely affect the accuracy of the delivered dose and the patient outcome. This research aims to investigate the inter-fraction setup variations occurring in two different scenarios of clinical practice: at the reference and at the current patient setups, when an image-guided system is used or not used, respectively. The results were used with the secondary aim of assessing the robustness of the patient setup procedure in use. Forty eight patients treated with volumetric modulated arc and intensity modulated therapies were included in this study. EPID-based in vivo dosimetry (IVD) was performed at the reference setup concomitantly with the weekly cone beam computed tomography acquisition and during the daily current setup. Three indices were analyzed: the ratio R between the reconstructed and planned isocenter doses, gamma% and the mean value of gamma from a transit dosimetry based on a two-dimensional gamma-analysis of the electronic portal images using 5% and 5 mm as dose difference and distance to agreement gamma criteria; they were considered in tolerance if R was within 5%, gamma% > 90% and gamma mean < 0.4. One thousand and sixteen EPID-based IVD were analyzed and 6.3% resulted out of the tolerance level. Setup errors represented the main cause of this off tolerance with an occurrence rate of 72.2%. The percentage of results out of tolerance obtained at the current setup was three times greater (9.5% vs 3.1%) than the one obtained at the reference setup, indicating weaknesses in the setup procedure. This study highlights an EPID-based IVD system's utility in the radiotherapy routine as part of the patient's treatment quality controls and to optimize (or confirm) the performed setup procedures' accuracy.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2019]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China [2]Department of Radiation Oncology, Radiation Oncology Key Laboratory of Sichuan Province, Sichuan Cancer Hospital & Institute, Chengdu, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43378 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号