FLASH radiotherapy using high-energy X-rays: Current status of PARTER platform in FLASH research

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China [2]Department of Oncology, NHC Key Laboratory of Nuclear Technology Medical Transformation (Mianyang Central Hospital), Mianyang Central Hospital, School of Medicine, University of Electronic Science and Technology, Mianyang 621000, China [3]Department of Radiotherapy Physics & Technology, West China Hospital, Sichuan University, Chengdu 610041, China [4]School of Radiation Medicine and Protection, Suzhou Medical College of Soochow University, Suzhou 215123, China [5]Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou 510060, China
出处:
ISSN:

关键词: FLASH radiotherapy Megavoltage X-ray PARTER platform Beam monitoring Dosimetry

摘要:
Recent studies indicated that ultrahigh dose rate (FLASH) radiation can reduce damage to normal tissue while maintaining anti-tumour activity compared to conventional dose rate (CONV) radiation. This paper provides a comprehensive description of the current status of the Platform for Advanced Radiotherapy Research (PARTER), which serves as the first experimental FLASH platform utilizing megavoltage X-rays and has facilitated numerous experiments.PARTER was established in 2019 based on a superconducting linac to support experimental FLASH studies using megavoltage X-rays. Continuous upgrades have been made to the accelerator, collimators, flattening filters, monitors, other auxiliary devices, and irradiation process in order to achieve optimal results. Passive and active dosimeters are employed for measuring dose distribution and to ensure traceability of radiation doses.The dose monitors and dosimeters demonstrate reliable performance with acceptable stability. At PARTER, the maximum mean dose rate is approximately 400 Gy/s at a surface-source distance of 20 cm (over 1000 Gy/s at smaller distances), with an instantaneous dose rate of approximately 8E5 Gy/s. Both passive and active dosimeters exhibit good linearity and agreement during FLASH X-ray irradiation. The monitors show good linearity to dose rate, with short-term fluctuations within 1.5% for the diamond monitor. The discrepancy between measured absorbed dose and dose protocol is typically less than 4%. The X-ray energy spectra on PARTER are comparable to those for megavoltage CONV linacs operating in flattening filter-free mode. The maximum field size of the FLASH beam is 4.5 cm × 4.5 cm. The FLASH dose profile demonstrates satisfactory flatness (1.04) and similar penumbra compared to clinical CONV linac, while the percentage depth dose curve of FLASH X-rays is steeper than that of the clinical megavoltage CONV X-ray.PARTER represents a pioneering platform for conducting megavolts FLASH X-ray irradiation in biological experiments. It effectively fulfills the requirements of preclinical research on megavoltage X-ray FLASH and undergoes continuous upgrades to meet increasingly demanding performance criteria.Copyright © 2023. Published by Elsevier B.V.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 1 区 医学
小类 | 2 区 肿瘤学 2 区 核医学
最新[2023]版:
大类 | 1 区 医学
小类 | 2 区 肿瘤学 2 区 核医学
JCR分区:
出版当年[2023]版:
Q1 ONCOLOGY Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 ONCOLOGY Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:53094 今日访问量:0 总访问量:4588 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号