文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu 610041, China
出处:
ISSN:

关键词: Brachytherapy 60Co source Monte Carlo Geant4 EGSnrc Dosimetry

摘要:
The purpose of this work was to obtain the dosimetric parameters of the new GZP3 60Co high-dose-rate afterloading system launched by the Nuclear Power Institute of China, which is comprised of two different 60Co sources.The Monte Carlo software Geant4 and EGSnrc were employed to derive accurate calculations of the dosimetric parameters of the new GZP3 60Co brachytherapy source in the range of 0-10 cm, following the formalism proposed by American Association of Physicists in Medicine reports TG43 and TG43U1. Results of the two Monte Carlo codes were compared to verify the accuracy of the data. The source was located in the center of a 30-cm-radius theoretical sphere water phantom.For channels 1 and 2 of the new GZP3 60Co afterloading system, the results of the dose-rate constant (Λ) were 1.115 cGy h-1 U-1 and 1.112 cGy h-1 U-1, and for channel 3 they were 1.116 cGy h-1 U-1 and 1.113 cGy h-1 U-1 according to the Geant4 and EGSnrc, respectively. The radial dose function in the range of 0.25-10.0 cm in a longitudinal direction was calculated, and the fitting formulas for the function were obtained. The polynomial function for the radial dose function and the anisotropy function (1D and 2D) with a [Formula: see text] of 0°-175° and an r of 0.5-10.0 cm were obtained. The curves of the radial function and the anisotropy function fitted well compared with the two Monte Carlo software.These dosimetric data sets can be used as input data for TPS calculations and quality control for the new GZP3 60Co afterloading system.© 2023. The Author(s).

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学 3 区 肿瘤学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学 3 区 肿瘤学
JCR分区:
出版当年[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ONCOLOGY
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu 610041, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:46666 今日访问量:3 总访问量:3332 更新日期:2024-11-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号