Improving dose delivery accuracy with EPID in vivo dosimetry: results from a multicenter study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]S. C. Fisica Sanitaria Firenze-Empoli, Medical Physics Unitof Radiation Oncology Dept., Azienda Sanitaria USL ToscanaCentro Florence, Via dell’Antella 58, 50012 Bagno a Ripoli,Firenze, Italy [2]UOC di Fisica Sanitaria, Radioterapia Oncologica edEmatologia, Fondazione Policlinico Universitario “A.Gemelli” IRCCS, Rome, Italy [3]Medical Physics, Candiolo Cancer Institute—FPO IRCCS,Turin, Italy [4]Department of Radiation Oncology, Sichuan Cancer Hospital,Chengdu, China [5]Dipartimento di Radioterapia, Università di Chieti, Chieti,Italy [6]Medical Physics Unit, Fondazione di ricerca e cura “GiovanniPaolo II”, Campobasso, Italy [7]OGP S. Camillo de Lellis, Rieti, Italy [8]AUSL Piacenza, Piacenza, Italy [9]S. C. Fisica Sanitaria Firenze-Empoli, Azienda Sanitaria USLToscana Centro Florence, Florence, Italy [10]S.C. Fisica Sanitaria, A.O. Ordine Mauriziano di Torino,Torino, Italy
出处:
ISSN:

关键词: Error detection Online dosimetry Online measurements Portal dosimetry Quality assurance

摘要:
Purpose: To investigate critical aspects and effectiveness of in vivo dosimetry (IVD) tests obtained by an electronic portal imaging device (EPID) in a multicenter and multisystem context. Materials and methods: Eight centers with three commercial systems—SoftDiso (SD, Best Medical Italy, Chianciano, Italy), Dosimetry Check (DC, Math Resolution, LCC), and PerFRACTION (PF, Sun Nuclear Corporation, SNC, Melbourne, FL)—collected IVD results for a total of 2002 patients and 32,276 tests. Data are summarized for IVD software, radiotherapy technique, and anatomical site. Every center reported the number of patients and tests analyzed, and the percentage of tests outside of the tolerance level (OTL%). OTL% was categorized as being due to incorrect patient setup, incorrect use of immobilization devices, incorrect dose computation, anatomical variations, and unknown causes. Results: The three systems use different approaches and customized alert indices, based on local protocols. For Volumetric Modulated Arc Therapy (VMAT) treatments OTL% mean values were up to 8.9% for SD, 18.0% for DC, and 16.0% for PF. Errors due to “anatomical variations” for head and neck were up to 9.0% for SD and DC and 8.0% for PF systems, while for abdomen and pelvis/prostate treatments were up to 9%, 17.0%, and 9.0% for SD, DC, and PF, respectively. The comparison among techniques gave 3% for Stereotactic Body Radiation Therapy, 7.0% (range 4.7–8.9%) for VMAT, 10.4% (range 7.0–12.2%) for Intensity Modulated Radiation Therapy, and 13.2% (range 8.8–21.0%) for 3D Conformal Radiation Therapy. Conclusion: The results obtained with different IVD software and among centers were consistent and showed an acceptable homogeneity. EPID IVD was effective in intercepting important errors. © 2021, Springer-Verlag GmbH, DE part of Springer Nature.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 2 区 核医学 3 区 肿瘤学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学 4 区 肿瘤学
JCR分区:
出版当年[2021]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q3 ONCOLOGY
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q3 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]S. C. Fisica Sanitaria Firenze-Empoli, Medical Physics Unitof Radiation Oncology Dept., Azienda Sanitaria USL ToscanaCentro Florence, Via dell’Antella 58, 50012 Bagno a Ripoli,Firenze, Italy
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43378 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题