A mid-infrared exhaled carbon dioxide isotope detection system based on 4.35 mu m quantum cascade laser

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]College of Control Science & Engineering, China University of Petroleum(East China), Qingdao 266580, PR China [2]Institute of Semiconductors, Chinese Academy of Sciences, Bejing 100083, PR China [3]Division of Thoracic Surgery, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu 610041,PR China
出处:
ISSN:

关键词: Carbon dioxide isotope exhaled gas QCL TDLAS GA-ELM Two-stage PID temperature control

摘要:
The carbon dioxide isotope in human exhaled gas can be used as an indicator to determine Helicobacter pylori (HP), the detection of carbon dioxide isotope in human exhaled gas is of great significance for the treatment of human diseases. Based on Tunable Diode Laser Absorption Spectroscopy (TDLAS), a carbon dioxide isotope detection system for exhaled gas was developed to detect the carbon dioxide isotope in human exhaled gas, a 4.35 mu m quantum cascade laser (QCL) and a 3 m optical path multi-pass gas cell (MPGC) were adopted in the detection system. The exhaled gas pretreatment system was designed to pass through human exhaled gas into the MPGC. The performance of the system was researched using a gas distribution station fitted with standard 12CO2 and 13CO2 concentrations. The results show that the limits of detection(LOD)of 12CO2 and 13CO2 reach up 0.0134 ppm and - 0.0149 ppm, respectively. The detection precision of the system is - 0.00214 parts per thousand with a 48 s averaging time. QCL-based mid-infrared detection system has higher sensitivity and lower detection limit compared with near-infrared detection system. The volume of MPGC is 250 ml, which is much less than the volume of normal human exhaled gas, therefore the majority of human exhaled gas can be filled with MPGC. Two-stage proportional-integral-derivative (PID) temperature control is adopted to eliminate the effect of drift of the spectrum due to the change of temperature, so that the stability of the system is improved. A high precision and high-speed Genetic Algorithm Extreme Learning Machine (GA-ELM) algorithm is applied for improving the concentration inversion precision of the system. Finally, the performance of detection system was validated at Sichuan Cancer Hospital for detecting carbon dioxide isotope in exhaled gas, and the verification results illustrate that the detection system has a very important application prospect in the field of exhaled gas detection.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 物理与天体物理
小类 | 2 区 物理:应用 2 区 光学
最新[2023]版:
大类 | 2 区 物理与天体物理
小类 | 2 区 光学 2 区 物理:应用
JCR分区:
出版当年[2022]版:
Q1 OPTICS Q1 PHYSICS, APPLIED
最新[2023]版:
Q1 OPTICS Q2 PHYSICS, APPLIED

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]College of Control Science & Engineering, China University of Petroleum(East China), Qingdao 266580, PR China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43370 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号