Deep learning applications in automatic segmentation and reconstruction in CT-based cervix brachytherapy

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Applied Nuclear Technology in Geosciences Key Laboratory of Sichuan Province, Chengdu University of Technology, Chengdu, China, [2]Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu, China
出处:
ISSN:

关键词: deep learning applicator segmentation brachytherapy cervical cancer dosimetric comparison

摘要:
Purpose: Motivated by recent advances in deep learning, the purpose of this study was to investigate a deep learning method in automatic segment and reconstruct applicators in computed tomography (CT) images for cervix brachytherapy treatment planning. Material and methods: U-Net model was developed for applicator segmentation in CT images. Sixty cervical cancer patients with Fletcher applicator were divided into training data and validation data according to ratio of 50 : 10, and another 10 patients with Fletcher applicator were employed to test the model. Dice similarity coefficient (DSC) and 95th percentile Hausdorff distance (HD95) were used to evaluate the model. Segmented applicator coordinates were calculated and applied into RT structure file. Tip error and shaft error of applicators were evaluated. Dosimetric differences between manual reconstruction and deep learning-based reconstruction were compared. Results: The averaged overall 10 test patients' DSC, HD95, and reconstruction time were 0.89, 1.66 mm, and 17.12 s, respectively. The average tip error was 0.80 mm, and the average shaft error was less than 0.50 mm. The dosimetric differences between manual reconstruction and automatic reconstruction were 0.29% for high-risk clinical target volume (HR-CTV) D90%, and less than 2.64% for organs at risk D2cc at a scenario of doubled maximum shaft error. Conclusions: We proposed a deep learning-based reconstruction method to localize Fletcher applicator in three-dimensional CT images. The achieved accuracy and efficiency confirmed our method as clinically attractive. It paves the way for the automation of brachytherapy treatment planning.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学 4 区 核医学
JCR分区:
出版当年[2021]版:
Q4 ONCOLOGY Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q4 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Applied Nuclear Technology in Geosciences Key Laboratory of Sichuan Province, Chengdu University of Technology, Chengdu, China, [2]Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu, China
通讯作者:
通讯机构: [2]Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu, China [*1]Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory of Sichuan Province, No. 55, the 4th Section, Renmin South Road, Chengdu, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43377 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号