高级检索
当前位置: 首页 > 详情页

Preliminary comparison of the registration effect of 4D-CBCT and 3D-CBCT in image-guided radiotherapy of Stage IA non-small-cell lung cancer

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Oncology, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao’an District, Shenzhen 518110, Guangdong Province, PR China [2]Department of Radiation Oncology, Sichuan Cancer Hospital, #55 Renmin Road South, Wuhou District, Chengdu 610041, Sichuan Province, PR China [3]Department of Rehabilitation, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao’an District, Shenzhen 518110, Guangdong Province, PR China [4]Department of Oncology and Hematology, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao’an District, Shenzhen 518110, Guangdong Province, PR China
出处:
ISSN:

关键词: 4D-CBCT Stage IA non-small-cell lung cancer image-guided radiotherapy 3D-CBCT registration

摘要:
In this study, we compared the registration effectiveness of 4D cone-beam computed tomography (CBCT) and 3D-CBCT for image-guided radiotherapy in 20 Stage IA non-small-cell lung cancer (NSCLC) patients. Patients underwent 4D-CBCT and 3D-CBCT immediately before radiotherapy, and the X-ray Volume Imaging software system was used for image registration. We performed automatic bone registration and soft tissue registration between 4D-CBCT or 3D-CBCT and 4D-CT images; the regions of interest (ROIs) were the vertebral body on the layer corresponding to the tumor and the internal target volume region. The relative displacement of the gross tumor volume between the 4D-CBCT end-expiratory phase sequence and 4D-CT was used to evaluate the registration error. Among the 20 patients (12 males, 8 females; 35-67 years old; median age, 52 years), 3 had central NSCLC and 17 had peripheral NSCLC, 8 in the upper or middle lobe and 12 in the lower lobe (maximum tumor diameter range, 18-27 mm). The internal motion range in three-dimensional space was 12.52 +/- 2.65 mm, accounting for 47.8 +/- 15.3% of the maximum diameter of each tumor. The errors of image-guided registration using 4D-CBCT and 3D-CBCT on the x (left-right), y (superior-inferior), z (anterior-posterior) axes, and 3D space were 0.80 +/- 0.21 mm and 1.08 +/- 0.25 mm, 2.02 +/- 0.46 mm and 3.30 +/- 0.53 mm, 0.52 +/- 0.16 mm and 0.85 +/- 0.24 mm, and 2.25 +/- 0.44 mm and 3.59 +/- 0.48 mm (all P < 0.001), respectively. Thus, 4D-CBCT is preferable to 3D-CBCT for image guidance in small pulmonary tumors because 4D-CBCT can reduce the uncertainty in the tumor location resulting from internal motion caused by respiratory movements, thereby increasing the image-guidance accuracy.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 3 区 生物学 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 生物学 4 区 肿瘤学 4 区 核医学
JCR分区:
出版当年[2017]版:
Q2 BIOLOGY Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 BIOLOGY Q3 ONCOLOGY Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Department of Oncology, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao’an District, Shenzhen 518110, Guangdong Province, PR China [2]Department of Radiation Oncology, Sichuan Cancer Hospital, #55 Renmin Road South, Wuhou District, Chengdu 610041, Sichuan Province, PR China
通讯作者:
通讯机构: [1]Department of Oncology, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao’an District, Shenzhen 518110, Guangdong Province, PR China [*1]Department of Oncology, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao’an District, Shenzhen 518110, Guangdong Province, PR China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43377 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号