机构:[1]Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University,[2]Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Chengdu, China四川省肿瘤医院
Purpose: To report an implementation method and the results of independent brachytherapy dose verification software (DVS). Material and methods: The DVS was developed based on Visual C++ and adopted a modular structure design. The DICOM RT files exported from a treatment planning system (TPS) were automatically loaded into the DVS. The DVS used the TG-43 formalism for dose calculation. A total of 15 cervical cancer patients who underwent brachytherapy were retrospectively selected to test the DVS. Dosimetric parameters and gamma analysis (0.1 cm, 5%) were used to evaluate the dose differences between the DVS and the TPS. Results: Compared with the TPS dose, the gamma pass rates of the dose calculated by the DVS were higher than 98%. For the clinical target volume (CTV), the dosimetric differences were less than 0.63% for D-90(%) and D-100%. For the bladder, rectum, and sigmoid, the agreement of D-0.1cc, D-1cc, and D-2cc were within a 0.78% level. Conclusions: With minimal human-computer interactions, the DVS can verify the accuracy of doses calculated by the TPS.
基金:
Key Research and Development Project of Sichuan [2017GZ0322, 2018GZ0197]
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类|4 区医学
小类|4 区肿瘤学4 区核医学
最新[2023]版:
大类|4 区医学
小类|4 区肿瘤学4 区核医学
JCR分区:
出版当年[2018]版:
Q3RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGINGQ4ONCOLOGY
最新[2023]版:
Q3RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGINGQ4ONCOLOGY
第一作者机构:[1]Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University,[2]Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Chengdu, China
通讯作者:
通讯机构:[1]Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University,[*1]Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University, No. 24 South Section 1, Yihuan Road, Chengdu, P.R. China, 610065
推荐引用方式(GB/T 7714):
Wang Xianliang,Wang Pei,Li Churong,et al.An automated dose verification software for brachytherapy[J].JOURNAL OF CONTEMPORARY BRACHYTHERAPY.2018,10(5):478-482.doi:10.5114/jcb.2018.79396.
APA:
Wang, Xianliang,Wang, Pei,Li, Churong,Wu, Zhangwen,Gou, Chengjun...&Hou, Qing.(2018).An automated dose verification software for brachytherapy.JOURNAL OF CONTEMPORARY BRACHYTHERAPY,10,(5)
MLA:
Wang, Xianliang,et al."An automated dose verification software for brachytherapy".JOURNAL OF CONTEMPORARY BRACHYTHERAPY 10..5(2018):478-482