Preliminary study of clinical application on IMRT three-dimensional dose verification-based EPID system

文献详情

资源类型:
机构: [1]Fujian Med Univ, Dept Radiat Oncol, Union Hosp, Fuzhou, Peoples R China; [2]Duke Kunshan Univ, Med Phys Grad Program, Kunshan, Peoples R China; [3]Sun Yat Sen Univ, State Key Lab Oncol South China, Canc Ctr, Guangzhou, Guangdong, Peoples R China
出处:
ISSN:

关键词: Delta4 electronic portal imaging system (EPID) intensity-modulated radiation therapy quality assurance three-dimensional dose verification

摘要:
The three-dimensional dose (3D) distribution of intensity-modulated radiation therapy (IMRT) was verified based on electronic portal imaging devices (EPIDs), and the results were analyzed. Thirty IMRT plans of different lesions were selected for 3D EPID-based dose verification. The gamma passing rates of the 3D dose verification-based EPID system (Edose, Version 3.01, Raydose, Guangdong, China) and Delta4 measurements were then compared with treatment planning system (TPS) calculations using global gamma criteria of 5%/3 mm, 3%/3 mm, and 2%/2 mm. Furthermore, the dose-volume histograms (DVHs) for planning target volumes (PTVs) as well as organs at risk (OARs) were analyzed using Edose. For dose verification of the 30 treatment plans, the average gamma passing rates of Edose reconstructions under the gamma criteria of 5%/3 mm, 3%/3 mm, and 2%/2 mm were (98.58 +/- 0.93)%, (95.67 +/- 1.97)%, and (83.13 +/- 4.53)%, respectively, whereas the Delta4 measurement results were (99.14% +/- 1.16)%, (95.81% +/- 2.88)%, and (84.74% +/- 7.00)%, respectively. The dose differences between Edose reconstructions and TPS calculations were within 3% for D-95%, D-98%, and D-mean in each PTV, with the exception that the D-98% of the PTV-clinical target volume (CTV) in esophageal carcinoma cases was (3.21 +/- 2.33)%. However, the larger dose deviations in OARs (such as lens, parotid gland, optic nerve, and spinal cord) can be determined based on DVHs. The difference was particularly obvious for OARs with small volumes; for example, the maximum dose deviation for the lens reached (-6.12 +/- 5.28)%. A comparison of the results obtained with Edose and Delta4 indicated that the Edose system could be applied for 3D pretreatment dose verification of IMRT. This system could also be utilized to evaluate the gamma passing rate of each treatment plan. Furthermore, the detailed dose distributions of PTVs and OARs could be indicated based on DVHs, providing additional reliable data for quality assurance in a clinic setting.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
第一作者:
第一作者机构: [1]Fujian Med Univ, Dept Radiat Oncol, Union Hosp, Fuzhou, Peoples R China;
通讯作者:
通讯机构: [1]Fujian Med Univ, Dept Radiat Oncol, Union Hosp, Fuzhou, Peoples R China; [3]Sun Yat Sen Univ, State Key Lab Oncol South China, Canc Ctr, Guangzhou, Guangdong, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号