高级检索
当前位置: 首页 > 详情页

Accuracy of Pulmonary Nodule Volumetry at Different Exposure Parameters in Low-Dose Computed Tomography: A Phantom Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
出处:
ISSN:

关键词: pulmonary nodule volumetry low-dose computed tomography phantom

摘要:
Objective To explore the exposure parameters with minimized radiation dose for accurate pulmonary nodule volumetry using low-dose computed tomography (LDCT). Methods An anthropomorphic chest phantom with 11 pulmonary nodules (6 solid nodules and 5 ground-glass opacities) was scanned using 256-slice multidetector computed tomography scanner at various tube voltage and current (combinations of 80, 100 and 120 kV with 10 to 30 mAs). Raw data sets were reconstructed using the hybrid iterative reconstruction method and nodule volume was calculated by a semiautomatic software. The absolute percentage error (APE) of nodule volume relating to the reference acquisition and contrast-to-noise ratio was measured. Results Nodule characteristic and tube voltage (P < 0.0001) as well as the interaction between nodule characteristic and tube voltage (P = 0.0026) contributed significantly to the mean difference of APE, while tube current did not (P = 0.21). Post hoc analysis revealed no significant difference was found between the APE at 100 kV and 120 kV in both solid nodules (2.3 +/- 0.4% vs 1.8 +/- 0.6%, P = 0.14) and ground-glass opacities (6.0 +/- 0.5% vs 4.9 +/- 0.6%, P = 0.11). Exploratory analyses further showed that the APE at 100 kV with 10 mAs did not differ from that at 120 kV with 30 mAs in both solid nodules (2.5 +/- 0.5% vs 1.7 +/- 0.3%, P = 0.025, corrected P = 0.20) and ground-glass opacities (6.4 +/- 0.4% vs 4.8 +/- 1.0%, P = 0.0084, corrected P = 0.068). Conclusions In our study, the exposure parameters with minimized radiation dose for accurate pulmonary nodule volumetry were found at 100 kV with 10 mAs, and the estimated effect radiation dose was as low as 0.2 mSv, suggesting the feasibility of further reducing radiation dose by decreasing tube voltage and current in LDCT lung screening.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2019]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Radiology, Sichuan Cancer Hospital & Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China [*1]Department of Radiology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, No. 55, Section 4, South Renmin Road, Chengdu, Sichuan, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号