Experimental study of applying shear wave elastography for examining effects of high intensity focused ultrasound ablation against subcutaneously implanted VX2 tumors in rabbits.

| 认领 | 导出 |

文献详情

资源类型:
机构: [1]Southern Med Univ, Nanfang Hosp, Nanfang PET Ctr, Guangzhou, Guangdong, Peoples R China; [2]Sun Yat Sen Univ, Ctr Canc, Dept Med Imaging, Guangzhou, Guangdong, Peoples R China; [3]Twelfth Peoples Hosp Guangzhou, Dept Clin Lab, Guangzhou, Guangdong, Peoples R China; [4]Chongqing Med Univ, Inst Ultrasound Engn Med, Coll Biomed Engn, Chongqing Key Lab Biomed Engn, Chongqing, Peoples R China; [5]Guangzhou Med Univ, Affiliated Hosp 2, Dept Ultrasound, Guangzhou, Guangdong, Peoples R China
出处:
ISSN:

关键词: Elastography High intensity focused ultrasound (HIFU) Ultrasound

摘要:
The aims of this study were to investigate the feasibility of applying Shear Wave Elastography (SWE) to evaluate the effects of High Intensity Focused Ultrasound (HIFU) ablation on Subcutaneously Implanted VX2 tumors in rabbits (R-SIVX2). The tumor hardness in a total of 20 R-SIVX2 models was measured at different time points using SWE following HIFU ablation treatment. In SWE images, the VX2 tumor appeared to be a homogeneous blue, and the average tumor hardness (E-mean) was 10.48 +/- 0.33 Kpa. Tumor hardness on D1 was the highest (E-mean = 97.45 +/- 23.08 Kpa), and decreased gradually over a 30 d period, with tumor hardness on D30 being similar to that on D0. The hardness uniformity (E-SD) in the Region of Interest (ROI) increased significantly as compared to before the ablation, indicating that HIFU ablation can cause acoustic environmental changes in the organizations of the ROI. There were significant differences among E-min, E-mean, E-max and E-SD at different time points (P=0.00). There was no significant difference in E-min (E-mean) between D0 and D30 (P < 0.05), but there was a significant difference between D0/D30 and D1/D7/D14 (P < 0.05). The E-max values among different time points showed statistical significance (P < 0.05), but the difference in E-SD between D3/D7 and D0/D1/D14/D30 was statistically significant (P < 0.05). In addition to 2D ultrasound and color flow signals, SWE can provide tissue hardness information when used for evaluating the efficacy of HIFU ablation, which can provide useful information for evaluating the effects of tumor ablation.

语种:
WOS:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
第一作者:
第一作者机构: [1]Southern Med Univ, Nanfang Hosp, Nanfang PET Ctr, Guangzhou, Guangdong, Peoples R China;
通讯作者:
通讯机构: [1]Southern Med Univ, Nanfang Hosp, Nanfang PET Ctr, Guangzhou, Guangdong, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43377 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号