高级检索
当前位置: 首页 > 详情页

An explainable transformer model integrating PET and tabular data for histologic grading and prognosis of follicular lymphoma: a multi-institutional digital biopsy study

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Nuclear Medicine, West China Hospital, Sichuan University, No.37, Guoxue Alley, Chengdu City, Sichuan Province 610041, China [2]West China Biomedical Big Data Center, West China Hospital, Sichuan University, No.37, Guoxue Alley, Chengdu City, Sichuan Province 610041, China [3]Department of Nuclear Medicine, Qilu Hospital of Shandong University, Jinan, Shandong, China [4]Department of Hematology, The First Affiliated Hospital of Xiamen University and Institute of Hematology, School of Medicine, Xiamen University, Xiamen, Fujian, China [5]Department of Nuclear Medicine, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, Jiangsu, China [6]Department of Pathology, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital, Nanjing, Jiangsu, China [7]Department of Hematology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, Jiangsu, China [8]Department of Nuclear Medicine, The First Affiliated Hospital of Nanjing Medical University, Jiangsu Province Hospital, No.321, Zhongshan Road, Nanjing City, Jiangsu Province 210008, China
出处:
ISSN:

关键词: Follicular lymphoma PET/CT Histologic grade Prognosis Transformer model Digital biopsy

摘要:
Pathological grade is a critical determinant of clinical outcomes and decision-making of follicular lymphoma (FL). This study aimed to develop a deep learning model as a digital biopsy for the non-invasive identification of FL grade.This study retrospectively included 513 FL patients from five independent hospital centers, randomly divided into training, internal validation, and external validation cohorts. A multimodal fusion Transformer model was developed integrating 3D PET tumor images with tabular data to predict FL grade. Additionally, the model is equipped with explainable modules, including Gradient-weighted Class Activation Mapping (Grad-CAM) for PET images, SHapley Additive exPlanations analysis for tabular data, and the calculation of predictive contribution ratios for both modalities, to enhance clinical interpretability and reliability. The predictive performance was evaluated using the area under the receiver operating characteristic curve (AUC) and accuracy, and its prognostic value was also assessed.The Transformer model demonstrated high accuracy in grading FL, with AUCs of 0.964-0.985 and accuracies of 90.2-96.7% in the training cohort, and similar performance in the validation cohorts (AUCs: 0.936-0.971, accuracies: 86.4-97.0%). Ablation studies confirmed that the fusion model outperformed single-modality models (AUCs: 0.974 - 0.956, accuracies: 89.8%-85.8%). Interpretability analysis revealed that PET images contributed 81-89% of the predictive value. Grad-CAM highlighted the tumor and peri-tumor regions. The model also effectively stratified patients by survival risk (P < 0.05), highlighting its prognostic value.Our study developed an explainable multimodal fusion Transformer model for accurate grading and prognosis of FL, with the potential to aid clinical decision-making.© 2025. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 核医学
第一作者:
第一作者机构: [1]Department of Nuclear Medicine, West China Hospital, Sichuan University, No.37, Guoxue Alley, Chengdu City, Sichuan Province 610041, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:53699 今日访问量:0 总访问量:4607 更新日期:2025-02-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号