The influence of beam optics asymmetric distribution on dose in scanning carbon-ion radiotherapy.

文献详情

资源类型:
Pubmed体系:
机构: [1]Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, 201800, China. [2]University of Chinese Academy of Sciences, Beijing, 100049, China. [3]College of Physical Science and Technology (College of Nuclear Science and Engineering), Sichuan University, Chengdu, China. [4]Department of Nuclear Medicine, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai, China. [5]Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Shanghai, China. [6]Shanghai Key Laboratory of Radiation Oncology (20dz2261000), Shanghai, China. [7]Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China.
出处:

摘要:
To quantify the influence of beam optics asymmetric distribution on dose.Nine reference cubic targets and corresponding plans with modulation widths (M) of 3, 6, and 9 cm and with center depths (CDs) of 6, 12, and 24 cm were generated by the treatment planning system (TPS). The Monte Carlo code FLUKA was used for simulating the dose distribution from the aforementioned original plans and the dose perturbation by varying ±5%, ±15%, ±20%, ±25%, and ±40% in spot full width half maximum to the X-direction while keeping consistent in the Y-direction. The dosimetric comparisons in dose deviation, γ-index analysis, lateral penumbra, and flatness were evaluated.The largest 3D absolute mean deviation was 15.0% ± 20.9% (mean ± standard deviation) in M3CD6, whereas with the variation from -15% to +20%, the values were below 5% for all cube plans. The lowest 2D γ-index passing rate was 80.6% with criteria of 2%-2 mm by a +40% variation in M3CD6. For the M9CD24 with a -40% variation, the maximum 1D dose deviations were 5.6% and 15.7% in the high-dose region and the edge of the radiation field, respectively. The maximum deviations of penumbra and flatness were 3.4 mm and 11.4%, respectively.The scenario of beam optics asymmetric showed relatively slight influence on the global dose distribution but severely affected dose on the edge of the radiation field. For scanning carbon-ion therapy facilities, beam spot lateral profile settings in TPS base data should be properly handled when beam optics asymmetry variation is over 15%.© 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
第一作者:
第一作者机构: [1]Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, 201800, China. [2]University of Chinese Academy of Sciences, Beijing, 100049, China.
通讯作者:
通讯机构: [1]Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, 201800, China. [5]Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Shanghai, China. [6]Shanghai Key Laboratory of Radiation Oncology (20dz2261000), Shanghai, China. [7]Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai, China. [*1]Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy, Shanghai,China [*2]Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号