两种冰冻切片包埋剂在解吸电喷雾电离质谱成像分析检测中的性能比较

[Performance Comparison of Two Cryosection Embedding Agents Used for Desorption Electrospray Ionization Mass Spectrometry Imaging].

文献详情

资源类型:
Pubmed体系:

收录情况: ◇ 统计源期刊 ◇ 北大核心 ◇ CSCD-C

机构: [1]四川大学华西医院 临床病理研究所 (成都 610041) [2]四川大学华西医院 国家卫生健康委员会移植工程与移植免疫重点实验室 (成都 610041) [3]四川大学华西医院 华西-华盛顿线粒体与代谢研究中心 (成都 610041) [4]四川大学华西医院 病理科 (成都 610041)
出处:
ISSN:

摘要:
To evaluate the potential effect of embedding with carboxylmethyl cellulose (CMC) and embedding with optimal cutting temperature (OCT) compound followed by washing with PBS (OCT-W) on the analysis of breast cancer tissue samples with desorption electrospray ionization mass spectrometry imaging (DESI-MSI).DESI-MSI of fresh frozen (FF) tissue samples, OCT-embedded samples, CMC-embedded samples, and OCT-W samples from the same breast cancer tumor tissue were performed. The ratio of maximum abundance ion was used to assess the reproducibility of DESI-MSI analysis. In addition, the effects of the treatment of each group were examined by comparing the characteristic ion species and the ion signal intensity detected by DESI-MSI.DESI-MSI of continuous sections of FF samples showed that the coefficient of variation (CV) of the pair-to-pair ratios of m/ z 281.25, m/ z 309.28 and m/ z 279.23 ions, the three ions with the highest intensity in the tumor region, were 19.61%, 20.74% and 10.18%, respectively. The characteristic ion species detected by DESI-MSI of CMC embedded tissue and the OCT-W tissue were almost the same, compared with those of the FF tumor tissue. However, ion species detected in OCT embedded samples were less than 50% of the FF samples. In terms of ion signal intensity, the CMC embedded tissue was not affected overall, while the signal of most of the characteristic ions of the OCT-W group showed decreased intensity (P<0.05).FF tissue sections and CMC-embedded samples can be used for DESI-MSI routine analysis. OCT embedding affects the feasibility of sample analysis whether or not the sample undergoes washing with PBS. CMC embedding agent is recommended if the tissue sections need to be fixated and supported due to small sample size, fragility, or other problems.Copyright© by Editorial Board of Journal of Sichuan University (Medical Sciences).

基金:
语种:
PubmedID:
第一作者:
第一作者机构: [1]四川大学华西医院 临床病理研究所 (成都 610041) [2]四川大学华西医院 国家卫生健康委员会移植工程与移植免疫重点实验室 (成都 610041)
通讯作者:
推荐引用方式(GB/T 7714):

资源点击量:43370 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号