高级检索
当前位置: 首页 > 详情页

Integrated microfluidic system for isolating exosome and analyzing protein marker PD-L1.

文献详情

资源类型:
Pubmed体系:

收录情况: ◇ EI

机构: [1]State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, [2]Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China [3]Department of Pulmonary and Critical Care Medicine, Zhongshan Hospital, Fudan University, Shanghai, 200032, China [4]Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, 646000, Sichuan, China [5]Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, 215123, China
出处:
ISSN:

关键词: Exosome PD-L1 Integrated system Microfluidic technology

摘要:
Exosomes are lipid-bilayered nanovesicles secreted by cells to mediate intercellular communication. Various kinds of biomolecules involved in exosomes offer non-invasive approaches for detecting or monitoring disease and developing targeted therapeutics. Here, we present an integrated microfluidic exosome isolation and detection system (EXID system) to analyze the abundance of the exosomal PD-L1 protein marker, which is a transmembrane protein expressed by tumors to suppress immune activation of T cells. By incorporating exosome isolation and biomarker labelling and quantification within a single microfluidic chip, our system reduced the total analysis time below 2 h. Using the EXID system, 7 categories of cell lines including cancer cell lines and control samples were profiled, where significant differences in the fluorescence intensity were observed with the limit of detection (LOD) down to 10.76 per microliter. Such noticeable variations in PD-L1 abundance among cancer cell lines highlighted the need of personalized treatments. Furthermore, 16 clinical samples from 7 post-treated cancer patients, 3 prior-treatment patients and 6 healthy controls, are tested, among which differences in sensitivity toward immune response were subsistent. Because the abundance of PD-L1 reflects the sensibility for immune response, our results provide useful guides to design immunotherapy strategies for different types of tumors.Copyright © 2021. Published by Elsevier B.V.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 1 区 工程技术
小类 | 1 区 生物工程与应用微生物 1 区 分析化学 1 区 纳米科技 1 区 生物物理 1 区 电化学
最新[2023]版:
大类 | 1 区 生物学
小类 | 1 区 生物物理 1 区 生物工程与应用微生物 1 区 分析化学 1 区 电化学 2 区 纳米科技
第一作者:
第一作者机构: [1]State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, [2]Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
共同第一作者:
通讯作者:
通讯机构: [1]State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, [2]Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China [*1]State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号