高级检索
当前位置: 首页 > 详情页

Addition of 3-methoxytyramine or chromogranin A to plasma free metanephrines as the initial test for pheochromocytoma and paraganglioma: Which is the best diagnostic strategy.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Endocrinology, Peking University First Hospital, Beijing, PR China. [2]Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, PR China. [3]Department of Clinical Chemistry, Guang Dong Bio-healtech Advanced Co., Ltd., Foshan, PR China. [4]Department of Urology, Peking University First Hospital, Beijing, PR China.
出处:
ISSN:

摘要:
Measurements of plasma free metanephrines (MNs), including MN and normetanephrine, provide high sensitivity and specificity for the diagnosis of pheochromocytoma and paraganglioma (PPGL). 3-Methoxytyramine (3-MT) and chromogranin A (CgA) may allow the detection of dopamine-producing or biochemically silent PPGL. The aim of this study was to evaluate whether measurements of plasma 3-MT or CgA as a supplement of plasma MNs offer a better diagnostic strategy for initial testing of PPGL.We enroled 125 patients who underwent surgery from 2015 to 2016 for our study and identified 33 patients with PPGL and 92 patients with non-PPGL masses.The levels of plasma free MNs and 3-MT were measured for all 125 patients using liquid chromatography-tandem mass spectrometry. Plasma CgA concentrations were determined using a radioimmunoassay. To evaluate the diagnostic performance of plasma free MNs, 3-MT and CgA, sensitivity and specificity were determined, and receiver operating characteristic curves were constructed.We found that combining 3-MT and MNs increased the diagnostic sensitivity from 93.9% (95% confidence interval [CI]: 78.4%-98.9%) to 97.0% (95% CI: 82.5%-99.8%). In contrast, addition of plasma CgA test reduced the diagnostic specificity significantly from 91.3% (95% CI: 83.1%-95.9%) to 75.0% (95% CI: 64.7%-83.2%).Here, we demonstrated that 3-MT represents a valuable supplementary test to plasma MNs, which can further enhance the sensitivity of the assay, while plasma CgA added no additional diagnostic value to MNs due to the lowered diagnostic specificity.© 2021 John Wiley & Sons Ltd.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 3 区 内分泌学与代谢
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 内分泌学与代谢
第一作者:
第一作者机构: [1]Department of Endocrinology, Peking University First Hospital, Beijing, PR China.
共同第一作者:
通讯作者:
通讯机构: [1]Department of Endocrinology, Peking University First Hospital, Beijing, PR China. [2]Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, PR China. [*1]Department of Endocrinology, Peking University First Hospital, 100034 Beijing, PR China. [*2]Laboratory of Interdisciplinary Research, Institute of Biophysics, Chinese Academy of Sciences, 10010 Beijing, PR China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号