高级检索
当前位置: 首页 > 详情页

Overview of the Dosimetry of Free Breathing and Breath Hold Forward Intensity Modulated Treatments in a Large Clinical Series of Left-Sided Breast Cancer Patients.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
出处:
ISSN:

摘要:
To compare the dosimetry of a large clinical series of left-sided breast cancer patients treated with forward intensity modulated radiation therapy in free breathing (FB) or in breath hold (BH).A total of 155 early-stage pT1c-T2N1 left breast carcinoma patients receiving whole breast irradiation were enrolled in this study. Computed tomography scans acquired in FB (75 patients) and in BH (82 patients) were exported to the treatment planning. Clinical target volume (CTV) and organs at risk (OARs) were contoured by an experienced radiation oncologist of the breast department; the planning target volume (PTV) was generated with an isotropic expansion of the CTV with a 3 mm margin in all directions, excluding the first 5 mm inside the body external contour. Patients were treated with a prescribed dose (Dp) of 50 Gy in 25 fractions. All plans were based on a tangential field in field technique with a 6 MV photon beam energy using two opposing tangential fields, each including 3 to 5 sub-segments. Treatment plans were optimized to achieve minimum 95% of the PTV covered by 95% isodose line and a mean dose () to the PTV equal to the Dp and keeping the organs at risk (OARs) doses as low as achievable. Dose volume histogram (DVH) endpoints for the PTV (D95, D98, Dm, Dmax), for heart and left lung (V5, V20, Dm) and for right lung and right breast (Dm and Dmax) were used to compare the dosimetry of FB and BH treatments. Data were analyzed with the Wilcoxon Cox test; P value < 0.05 was considered statistically significant.The analysis showed no significant difference for PTV D95, D98, Dm, Dmax, and volume (P = 0.329, P = 0.456, P = 0.566, P = 0.067, P = 0.482, respectively) between BH and FB groups. Comparing the dosimetry of OARs, we recorded significantly lower values for patients in the BH group: heart Dm (1.7 Gy vs 5.3 Gy), V5 (3.7% vs 26.0%) and V20 (0.4% vs 3.0%); left lung V5 (29.5% vs 38.0%) and V20 (13.6% vs 15.7%); right lung Dm (0.1% vs 2.5%), right breast Dm (0.2 Gy vs 1.7 Gy). While, a slight lower lung left Dm value (8.0 Gy vs 8.6 Gy), not statistically significant (P = 0.106) was registered for BH group. The OARs dosimetry obtained for the FB patients and the corresponding percentage difference obtained for the BH group is shown in the Table below.The use of BH in the clinical practice may be the best option for left breast RT reducing the irradiation of heart, left lung, and of right lung and right breast, without compromising target coverage.Copyright © 2021. Published by Elsevier Inc.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 2 区 肿瘤学 2 区 核医学
最新[2023]版:
大类 | 1 区 医学
小类 | 2 区 肿瘤学 2 区 核医学
JCR分区:
出版当年[2021]版:
Q1 ONCOLOGY Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 ONCOLOGY Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:53094 今日访问量:0 总访问量:4588 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号