Dosimetric evaluation of synthetic CT image generated using a neural network for MR-only brain radiotherapy.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Key Laboratory of Radiation Physics and Technology of the Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, Sichuan, China [2]Department of Radiation Oncology, Radiation Oncology Key Laboratory Of Sichuan Province, Sichuan Cancer Hospital & Institute, Chengdu, Sichuan, China [3]Department of Radiotherapy, West China Hospital of Sichuan University, Chengdu, Sichuan, China
出处:
ISSN:

摘要:
The magnetic resonance (MR)-only radiotherapy workflow is urged by the increasing use of MR image for the identification and delineation of tumors, while a fast generation of synthetic computer tomography (sCT) image from MR image for dose calculation remains one of the key challenges to the workflow. This study aimed to develop a neural network to generate the sCT in brain site and evaluate the dosimetry accuracy. A generative adversarial network (GAN) was developed to translate T1-weighted MRI to sCT. First, the "U-net" shaped encoder-decoder network with some image translation-specific modifications was trained to generate sCT, then the discriminator network was adversarially trained to distinguish between synthetic and real CT images. We enrolled 37 brain cancer patients acquiring both CT and MRI for treatment position simulation. Twenty-seven pairs of 2D T1-weighted MR images and rigidly registered CT image were used to train the GAN model, and the remaining 10 pairs were used to evaluate the model performance through the metric of mean absolute error. Furthermore, the clinical Volume Modulated Arc Therapy plan was calculated on both sCT and real CT, followed by gamma analysis and comparison of dose-volume histogram. On average, only 15 s were needed to generate one sCT from one T1-weighted MRI. The mean absolute error between synthetic and real CT was 60.52 ± 13.32 Housefield Unit over 5-fold cross validation. For dose distribution on sCT and CT, the average pass rates of gamma analysis using the 3%/3 mm and 2%/2 mm criteria were 99.76% and 97.25% over testing patients, respectively. For parameters of dose-volume histogram for both target and organs at risk, no significant differences were found between both plans. The GAN model can generate synthetic CT from one single MRI sequence within seconds, and a state-of-art accuracy of CT number and dosimetry was achieved. © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2021]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Key Laboratory of Radiation Physics and Technology of the Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, Sichuan, China [2]Department of Radiation Oncology, Radiation Oncology Key Laboratory Of Sichuan Province, Sichuan Cancer Hospital & Institute, Chengdu, Sichuan, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号