高级检索
当前位置: 首页 > 详情页

A reusable localized surface plasmon resonance biosensor for quantitative detection of serum squamous cell carcinoma antigen in cervical cancer patients based on silver nanoparticles array.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Gynecology and Obstetrics, West China Second University Hospital, Sichuan University, [2]State Key Laboratory of Optical Technologies for Microfabrication, Institute of Optics and Electronics, Chinese Academy of Science, Chengdu, Sichuan, People’s Republic of China
出处:
ISSN:

关键词: localized surface plasmon resonance nanotechnology biosensor cervical cancer biomarker squamous cell carcinoma antigen

摘要:
Squamous cell carcinoma antigen (SCCa), as a tumor biomarker, plays an important role in adjuvant diagnosis, treatment evaluation, and prognosis prediction for cervical cancer patients. Localized surface plasmon resonance (LSPR) technique based on noble metal nanoparticles bypasses the disadvantages of traditional testing strategies, in terms of free-labeling, short assay time, good sensitivity, and selectivity. Herein, we develop a novel and reusable LSPR biosensor for the detection of SCCa. First, a triangle-shaped silver nanoparticle array was fabricated using the nanosphere lithography method. Next, we investigated and verified the feasibility of amino coupling method using 11-mercaptoundecanoic acid (MUA) to form a functionalized chip surface with monoclonal anti-SCCa antibodies on the silver nanoparticles for distinct detection of SCCa. Different concentrations of SCCa were successfully tested in both buffer and human serum by the ultrasensitive and specific LSPR system, with a linear quantitative detection range of 0.1-1,000 pM under optimal conditions. With appropriate regeneration solution, for example 50 mM glycine-HCl (pH 2.0), the LSPR biosensor featured effective fabrication reproducibility, which reduced both production cost and testing time. Our study represents the first application of the LSPR biosensor in cervical cancer, and demonstrates that the rapid, simple, and reusable nanochip can serve as a potential alternative for clinical serological diagnosis of SCCa in cervical cancer patients.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 2 区 工程技术
小类 | 2 区 药学 3 区 纳米科技
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 药学 3 区 纳米科技
第一作者:
第一作者机构: [1]Department of Gynecology and Obstetrics, West China Second University Hospital, Sichuan University,
通讯作者:
通讯机构: [1]Department of Gynecology and Obstetrics, West China Second University Hospital, Sichuan University, [*1]Department of Gynecology and Obstetrics, West China Second University Hospital, Sichuan University, Chengdu, China. No 20, Block 3, Renminnan Road, Chengdu, Sichuan, People’s Republic of China (610041)
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号