高级检索
当前位置: 首页 > 详情页

Savitzky-Golay filter based contrast-enhanced ultrasound quantification in hepatic tumors: Methodology and its correlation with tumor angiogenesis.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China. [2]Department of Diagnostic Ultrasound, Second University Hospital of Sichuan University, Cheng Du, Sichuan, China. [3]Shanghai Institute of Medical Imaging, Shanghai, China. [4]Medical Imaging College, Shanghai University of Medicine and Health Sciences, Shanghai, China.
出处:
ISSN:

关键词: Contrast-enhanced ultrasound Savitzky-Golay filter methodology hepatocellular carcinoma colorectal cancer neovascularization

摘要:
Savitzky-Golay filter is a digital filter used in data smoothing, we introduced a contrast-enhanced ultrasound (CEUS) quantification software based on the filter (SGCQ). To explore the methodology of analyzing hepatic tumors hemodynamics applying SGCQ software and the correlation between SGCQ parameters and hepatocellular carcinoma (HCC) angiogenesis. Nighty-seven right-lobe located hepatic mass cases (15 females and 82 males, mean age 58±10y, mean lesion size: 39.9±11.6 mm) underwent CEUS scan preoperatively and had a final diagnosis of HCC (n = 52) or colorectal cancer metastatic liver tumors (MLT, n = 45) were included. CEUS was carried out using a 1-5 MHz convex probe. The CEUS clips were recorded and analyzed off-line to obtain the parameters. The parameters were analyzed by 3 observers separately to investigate inter-observer variability. Parameters were compared between tumor and adjacent liver and between different tumors. Immunohistochemistry was used to evaluate the microvessel density (MVD) of HCC, and the correlation between the parameters and MVD was analyzed. Intraclass correlation coefficient (ICC) of all parameters were greater than 0.75 except wash-in slope (a3) and time to peak (TTP) of adjacent liver. The parameters of a3, wash-out slope (a2), perfusion time (PT) and area under the curve (AUC) were significantly different between HCC and liver. The a2, a3, AUC, PT and enhanced intensity (EI) were significantly different between MLT and liver. AUC, a2, a3, da1 and dPI were significantly different between HCC and MLT. AUC, a2 and EI correlated with MVD. SGCQ software quantification have good consistency among three observers, the parameters of SGCQ can display the hemodynamics of HCC and MLT and the difference between them. AUC and EI can serve as useful biomarkers in tumor angiogenesis evaluation.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 血液学 4 区 外周血管病
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 血液学 4 区 外周血管病
第一作者:
第一作者机构: [1]Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China. [2]Department of Diagnostic Ultrasound, Second University Hospital of Sichuan University, Cheng Du, Sichuan, China.
通讯作者:
通讯机构: [1]Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai, China. [4]Medical Imaging College, Shanghai University of Medicine and Health Sciences, Shanghai, China. [*1]Department of Ultrasound, Zhongshan Hospital of Fudan University, Shanghai 200032, China. [*2]Medical Imaging College, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号