机构:[1]Department of nursing, Sichuan Cancer Hospital, Chengdu, P. R. China四川省肿瘤医院[2]Central cenous catheterization room, Sichuan Cancer Hospital, Chengdu, P. R. China四川省肿瘤医院[3]Department of thoracic surgery, Sichuan Cancer Hospital, Chengdu, P. R. China外科中心胸外科中心四川省肿瘤医院胸外科[4]Department of radiotherapy, Sichuan Cancer Hospital, Chengdu, P. R. China四川省肿瘤医院[5]Department of medical oncology, Sichuan Cancer Hospital, Chengdu, P. R. China四川省肿瘤医院
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy.
第一作者机构:[1]Department of nursing, Sichuan Cancer Hospital, Chengdu, P. R. China
通讯作者:
推荐引用方式(GB/T 7714):
Wang Guorong,Guo Ling,Jiang Bin,et al.Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement[J].PLOS ONE.2015,10(4):doi:10.1371/journal.pone.0124846.
APA:
Wang, Guorong,Guo, Ling,Jiang, Bin,Huang, Min,Zhang, Jian&Qin, Ying.(2015).Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement.PLOS ONE,10,(4)
MLA:
Wang, Guorong,et al."Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement".PLOS ONE 10..4(2015)