Factors Influencing Intracavitary Electrocardiographic P-Wave Changes during Central Venous Catheter Placement

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of nursing, Sichuan Cancer Hospital, Chengdu, P. R. China [2]Central cenous catheterization room, Sichuan Cancer Hospital, Chengdu, P. R. China [3]Department of thoracic surgery, Sichuan Cancer Hospital, Chengdu, P. R. China [4]Department of radiotherapy, Sichuan Cancer Hospital, Chengdu, P. R. China [5]Department of medical oncology, Sichuan Cancer Hospital, Chengdu, P. R. China
出处:
ISSN:

摘要:
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 3 区 生物
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2015]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Department of nursing, Sichuan Cancer Hospital, Chengdu, P. R. China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:55381 今日访问量:3 总访问量:4689 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号