高级检索
当前位置: 首页 > 详情页

Transperineal 3-Core Magnetic Resonance Imaging Ultrasound Fusion Targeted Plus Laterally 6-Core Systematic Biopsy in Prostate Cancer Diagnosis

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Urology, Institute of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China [2]Department of Medical Ultrasound, West China Hospital, Sichuan University, Chengdu, Sichuan, China [3]Department of Pathology and Laboratory of Pathology, State Key Laboratory of Biotherapy, West China Hospital, West China Medical School, Sichuan University, Chengdu, Sichuan, China [4]Department of Molecular Oncology, Institute of Oncology Research (IOR), Oncology Institute of Southern Switzerland (IOSI), Bellinzona, Switzerland [5]School of Science and Engineering, University of Dundee, Scotland, UK
出处:
ISSN:

关键词: Prostate biopsy Prostate multiparametric magnetic resonance imaging Prostatic neoplasms

摘要:
It is important to explore strategies reducing the number of SB cores taken to minimize biopsy-related morbidity and patient's discomfort during biopsy. This study aims to optimize prostate biopsy procedures by reducing the number of systematic biopsy (SB) cores while preserving cancer detection rates in the era of combined biopsy.We prospectively recruited patients with ≥1 magnetic resonance imaging (MRI) lesions and they underwent transperineal combined 12-core SB+3-core targeted prostate biopsy (TB, reference standard). New strategy was defined as a laterally 6-core SB+3-core TB. Patients were served as their own control. Detection rates for overall prostate cancer (PCa) and clinically significant PCa (csPCa) were compared among the standard SB, MRI-TB, 6-core SB +3-core TB, and reference standard. Pathology consistency was assessed using the Kappa test.A total of 204 men were included, of which 111 (54.41%) and 92 (45.10%) harbored overall PCa and csPCa. Referenced combined biopsy detected significantly 6.86% (P = .0005) or 4.90% (P = .0044) more csPCa than performing only SB or 3-core TB, but was comparable to the new biopsy strategy. (45.10% vs. 43.14%, P = .1336) Similar results persisted when limiting patients in biopsy-naïve men or stratified by Prostate Imaging Reporting and Data System scores, PSAD, and index lesion parameters. Additionally, performing 6-core SB+3-core TB demonstrated high consistency with reference standard in grade group distribution (Kappa coefficient: 0.952 for all, 0.961 for biopsy-naïve men) and achieved superior sensitivity of 95.7% (All: 95% CI: 89.2%-99.8%) and 96.9% (Biopsy-naïve: 95% CI: 91.1%-99.7%), respectively.The 6-core SB+3-core TB approach maintains expected detection rates while reducing the total core count, offering a promising alternative to the reference standard, which may help to tailor transperineal combined biopsy procedures.Copyright © 2024 Elsevier Inc. All rights reserved.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 肿瘤学 3 区 泌尿学与肾脏学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 肿瘤学 3 区 泌尿学与肾脏学
第一作者:
第一作者机构: [1]Department of Urology, Institute of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Urology, Institute of Urology, West China Hospital, Sichuan University, Chengdu, Sichuan, China [4]Department of Molecular Oncology, Institute of Oncology Research (IOR), Oncology Institute of Southern Switzerland (IOSI), Bellinzona, Switzerland
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

[1]Utilization trend of prebiopsy multiparametric magnetic resonance imaging and its impact on prostate cancer detection: Real-world insights from a high-volume center in southwest China [2]The Impact of Prostate Volume on Prostate Cancer Detection: Comparing Magnetic Resonance Imaging with Transrectal Ultrasound in Biopsy-naïve Men [3]Combining clinical parameters and multiparametric magnetic resonance imaging to stratify biopsy-naïve men for an optimum diagnostic strategy with prostate-specific antigen 4 ng ml-1 to 10 ng ml-1 [4]The role of prostate-specific antigen density and negative multiparametric magnetic resonance imaging in excluding prostate cancer for biopsy-naïve men: clinical outcomes from a high-volume center in China. [5]Transperineal Magnetic Resonance Imaging-Targeted Biopsy May Perform Better Than Transrectal Route in the Detection of Clinically Significant Prostate Cancer: Systematic Review and Meta-analysis. [6]Efficacy and safety of the new biopsy strategy combining 6-core systematic and 3-core MRI-targeted biopsy in the detection of prostate cancer: Study protocol for a randomized controlled trial [7]The optimal core number and site for MRI-targeted biopsy of prostate? A systematic review and pooled analysis. [8]Diagnostic Role of Magnetic Resonance Imaging-Targeted Biopsy for Prostate Cancer in Biopsy-Naïve Men: A Meta-Analysis. [9]Is Additional Systematic Biopsy Necessary in All Initial Prostate Biopsy Patients With Abnormal MRI? [10]The value of transperineal apical prostate biopsy in predicting urethral/apical margin status after radical prostatectomy.

资源点击量:43377 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号