Intravoxel Incoherent Motion Diffusion-Weighted MR Imaging and Venous Tumor Thrombus Consistency in Renal Cell Carcinoma

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China. [2]Department of Radiology, Armed Police Force Hospital of Sichuan, Leshan, Sichuan, China. [3]Department of Radiology, Sixth Medical Center, Chinese PLA General Hospital, Beijing, China. [4]Department of Pathology, First Medical Center, Chinese PLA General Hospital, Beijing, China. [5]Department of Urology, Chinese PLA General Hospital, Beijing, China. [6]Department of Innovative Medical Research, Hospital Management Institute, Chinese PLA General Hospital, Beijing, China
出处:
ISSN:

摘要:
Venous tumor thrombus (VTT) consistency of renal cell carcinoma (RCC) is an important consideration in nephrectomy plus thrombectomy. However, evaluation of VTT consistency through preoperative MR imaging is lacking.To evaluate VTT consistency of RCC through intravoxel incoherent motion-diffusion weighted imaging (IVIM-DWI) derived parameters (Dt , Dp , f, and ADC) and the apparent diffusion coefficient (ADC) value.Retrospective.One hundred and nineteen patients (aged 55.8 ± 11.5 years, 85 male) with histologically-proven RCC and VTT who underwent radical resection.3.0-T; two-dimensional single-shot diffusion-weighted echo planar imaging sequence at 9 b-values (0-800 s/mm2 ).IVIM parameters and ADC values of the primary tumor and the VTT were calculated. The VTT consistency (friable vs. solid) was determined through intraoperative findings of two urologists. The accuracy of VTT consistency classification based on the individual IVIM parameters of primary tumors and of VTT, and based on models combining parameters, was assessed. Type of operation, intra-operative blood loss, and operation length were recorded.Shapiro-Wilk test; Mann-Whitney U test; Student's t-test; Chi-square test; Receiver operating characteristic (ROC) analysis. Statistical significance level was P < 0.05.Of the enrolled 119 patients, 33 patients (27.7%) had friable VTT. Patients with friable VTT were significantly more likely to experience open surgery, have significantly more intraoperative blood loss, and significantly longer operative duration. The area under the ROC curve (AUC) values of Dt of the primary tumor and VTT in classifying VTT consistency were 0.758 (95% CI 0.671-0.832) and 0.712 (95% CI 0.622-0.792), respectively. The AUC value of the model combining Dp and Dt of VTT was 0.800 (95% CI 0.717-0.868). Furthermore, the AUC of the model combining Dp and Dt of VTT and Dt of the primary tumor was 0.886 (95% CI 0.814-0.937).IVIM-derived parameters had the potential to predict VTT consistency of RCC.3 Technical Efficacy: Stage 2.© 2023 International Society for Magnetic Resonance in Medicine.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学
第一作者:
第一作者机构: [1]Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China. [2]Department of Radiology, Armed Police Force Hospital of Sichuan, Leshan, Sichuan, China.
共同第一作者:
通讯作者:
通讯机构: [1]Department of Radiology, First Medical Center, Chinese PLA General Hospital, Beijing, China. [5]Department of Urology, Chinese PLA General Hospital, Beijing, China. [6]Department of Innovative Medical Research, Hospital Management Institute, Chinese PLA General Hospital, Beijing, China [*1]No. 28, Fuxing Road, Haidian District, Beijing 100853, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43377 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号