高级检索
当前位置: 首页 > 详情页

High cut-off membranes in patients requiring renal replacement therapy: a systematic review and meta-analysis

文献详情

资源类型:
Pubmed体系:

收录情况: ◇ 统计源期刊 ◇ CSCD-C ◇ 卓越:领军期刊 ◇ 中华系列

机构: [1]Division of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, Sichuan 610041, China. [2]Division of Nephrology, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Beijing 100034, China. [3]Preventive Medicine, West China School of Public Health, Sichuan University, Chengdu, Sichuan 610041, China.
出处:
ISSN:

摘要:
Whether high cut-off (HCO) membranes are more effective than high-flux (HF) membranes in patients requiring renal replacement therapy (RRT) remains controversial. The aim of this systematic review was to investigate the efficacy of HCO membranes regarding the clearance of inflammation-related mediators, β2-microglobulin and urea; albumin loss; and all-cause mortality in patients requiring RRT.We searched all relevant studies on PubMed, Embase, Web of Science, the Cochrane Library, and China National Knowledge Infrastructure, with no language or publication year restrictions. Two reviewers independently selected studies and extracted data using a prespecified extraction instrument. Only randomized controlled trials (RCTs) were included. Summary estimates of standardized mean differences (SMDs) or weighted mean differences (WMDs) and risk ratios (RRs) were obtained by fixed-effects or random-effects models. Sensitivity analyses and subgroup analyses were performed to determine the source of heterogeneity.Nineteen RCTs involving 710 participants were included in this systematic review. Compared with HF membranes, HCO membranes were more effective in reducing the plasma level of interleukin-6 (IL-6) (SMD -0.25, 95% confidence interval (CI) -0.48 to -0.01, P   =  0.04, I2  = 63.8%); however, no difference was observed in the clearance of tumor necrosis factor-α (TNF-α) (SMD 0.03, 95% CI -0.27 to 0.33, P  = 0.84, I2  = 4.3%), IL-10 (SMD 0.22, 95% CI -0.12 to 0.55, P  = 0.21, I2  = 0.0%), or urea (WMD -0.27, 95% CI -2.77 to 2.23, P  = 0.83, I2  = 19.6%). In addition, a more significant reduction ratio of β 2 -microglobulin (WMD 14.8, 95% CI 3.78 to 25.82, P  = 0.01, I2  = 88.3%) and a more obvious loss of albumin (WMD -0.25, 95% CI -0.35 to -0.16, P  < 0.01, I2  = 40.8%) could be observed with the treatment of HCO membranes. For all-cause mortality, there was no difference between the two groups (risk ratio [RR] 1.10, 95% CI 0.87 to 1.40, P  = 0.43, I2  = 0.0%).Compared with HF membranes, HCO membranes might have additional benefits on the clearance of IL-6 and β 2-microglobulin but not on TNF-α, IL-10, and urea. Albumin loss is more serious with the treatment of HCO membranes. There was no difference in all-cause mortality between HCO and HF membranes. Further larger high-quality RCTs are needed to strengthen the effects of HCO membranes.Copyright © 2023 The Chinese Medical Association, produced by Wolters Kluwer, Inc. under the CC-BY-NC-ND license.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
第一作者:
第一作者机构: [1]Division of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, Sichuan 610041, China.
通讯作者:
通讯机构: [1]Division of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, Sichuan 610041, China. [*1]Division of Nephrology, Kidney Research Institute, West China Hospital of Sichuan University, Chengdu, Sichuan 610041, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号