高级检索
当前位置: 首页 > 详情页

Three-dimensional printed customized uncemented unipolar prosthesis combined with ligament reconstruction for tumorous defect of the distal femur in children

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Orthopedics, Orthopaedic Research Institute, West ChinaHospital, Sichuan University, No.37 Guo Xue Xiang, Chengdu 610041, People’sRepublic of China [2]Model Worker and Craftsman Talent Innovation Workshopof Sichuan province , West China Hospital, Sichuan University, Chengdu,People’s Republic of China
出处:

关键词: Distal femur Prosthesis 3D-printed Hemiarthroplasty Limb length discrepancy

摘要:
Hemiarthroplasty following tumor resection of the distal femur in children provides a chance to preserve the proximal tibial physis for limb elongation. Based on three-dimensional (3D) printing technology, the uncemented unipolar prosthesis with joint stability reinforced structures (JSRSs) was custom-designed for our cases. This study aimed to describe the design and assess the short-term outcomes of this refined prosthetic hemiarthroplasty.Seven patients (four females and three males) received 3D-printed customized uncemented unipolar prosthesis for hemiarthroplasty after removal of the distal femur, from September 2019 to October 2020 at our Orthopedics department. The limb function, growth of the preserved proximal tibial physis, joint stability, and limb length discrepancy (LLD) were assessed. Complications were recorded.Six patients survived with no evidence of metastasis or local recurrence at the last follow-up, and one patient died of lung metastasis at 19 months postoperatively. Follow-up ranged from 19 to 32 months, with an average of 26 months. Elongation of the tibia was observed in all cases. At the last follow-up, four patients exhibited equal growth length compared with the healthy contralateral tibia. LLD ranged from 0.8 to 1.6 cm with a mean of 1.3 cm. The average knee range of motion was 95.3° of flexion and 4.5° of extension. All patients achieved satisfactory postoperative limb function with a mean MSTS score of 25.8. The results of the drawer, Lachman, and pivot shift tests were negative in all patients. During follow-up, painless joint space narrowing was observed in two patients. The screw for ligament fixation loosened in one of the seven patients at 17 months postoperatively. No subluxation of the joint, angular deformity, or breakage of the implant was detected in the remaining patients.3D-printed customized uncemented unipolar prosthesis with JSRS would be a good choice for reconstructing tumorous defect in the distal femur in children.© 2022. The Author(s).

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 4 区 骨科 4 区 风湿病学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 骨科 3 区 风湿病学
第一作者:
第一作者机构: [1]Department of Orthopedics, Orthopaedic Research Institute, West ChinaHospital, Sichuan University, No.37 Guo Xue Xiang, Chengdu 610041, People’sRepublic of China [2]Model Worker and Craftsman Talent Innovation Workshopof Sichuan province , West China Hospital, Sichuan University, Chengdu,People’s Republic of China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Orthopedics, Orthopaedic Research Institute, West ChinaHospital, Sichuan University, No.37 Guo Xue Xiang, Chengdu 610041, People’sRepublic of China [2]Model Worker and Craftsman Talent Innovation Workshopof Sichuan province , West China Hospital, Sichuan University, Chengdu,People’s Republic of China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:43389 今日访问量:0 总访问量:3120 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 四川省肿瘤医院 技术支持:重庆聚合科技有限公司 地址:成都市人民南路四段55号